Home >> Lexus >> 2007 >> IS 250 AWD >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System (4GR-FSE) - DTC P0607 - DTC P2A03, DTC U0101 >> DTC P2401 Evaporative Emission System Leak Detection Pump Control Circuit Low; DTC P2402 Evaporative Emission System Leak Detection Pump Control Circuit High >> Typical Enabling Conditions
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Typical Enabling Conditions

TYPICAL ENABLING CONDITIONS

Monitor runs whenever following DTCs not present None
EVAP key-off monitor runs when all of following conditions are met: - - -
Atmospheric pressure 70 to 110 kPa (525 to 825 mmHg)
Battery voltage 10.5 V or more
Vehicle speed Below 2.5 mph (4 km/h)
Engine switch OFF
Time after engine stop 5, 7 or 9.5 hours
FTP sensor malfunction (P0450, P0451, P0452 and P0453) Not detected
EVAP VSV Not operated by scan tool
Vent valve Not operated by scan tool
Leak detection pump Not operated by scan tool
Both of following conditions are met before key OFF: Conditions 1 and 2
1. Duration that vehicle driven 5 minutes or more
2. EVAP purge operation Performed
ECT 4.4 to 35°C (40 to 95°F)
IAT 4.4 to 35°C (40 to 95°F)
  1. Key-off monitor sequence 1 to 8 
    1. Atmospheric pressure 
      ATMOSPHERIC PRESSURE

      Next sequence is run if following condition is met: -
      Atmospheric pressure change Less than 0.3 kPa (2.25 mmHg) for 1 second
    2. First reference pressure 
      FIRST REFERENCE PRESSURE

      Next sequence is run if all of following conditions are met: Conditions 1, 2 and 3
      1. FTP when 4 seconds after reference pressure measurement -1 kPa (-7.5 mmHg) or less
      2. Reference pressure -4.85 to -1.05 kPa (-36.38 to -7.87 mmHg)
      3. Reference pressure Saturated within 1 minute
    3. Vent valve stuck closed check 
      VENT VALVE STUCK CLOSED CHECK

      Next sequence is run if following condition is met: -
      EVAP pressure change after vent valve is ON 0.3 kPa (2.25 mmHg) or more
    4. Vacuum introduction and leak 
      VACUUM INTRODUCTION AND LEAK

      Next sequence is run if following condition is met: -
      Vacuum introduction time 15 minutes or less
    5. EVAP VSV stuck closed check 
      EVAP VSV STUCK CLOSED CHECK

      Next sequence is run if following condition is met: -
      FTP change after purge VSV ON 0.3 kPa (2.25 mmHg) or more
    6. Second reference pressure measurement 
      SECOND REFERENCE PRESSURE MEASUREMENT

      Next sequence is run if all of following conditions are met: Conditions 1,2,3 and 4
      1. FTP just after reference pressure measurement -1 kPa (-7.5 mmHg) or less
      2. Reference pressure -4.85 to -1.05 kPa (-36.38 to -7.87 mmHg)
      3. Reference pressure Saturated within 1 minute
      4. Reference pressure difference between first and second Less than 0.7 kPa (5.25 mmHg)
    7. Leak check 
      LEAK CHECK

      Next sequence is run if following condition is met: -
      FTP when vacuum introduction was complete Less than second reference pressure
    8. Atmospheric pressure 
      ATMOSPHERIC PRESSURE

      Monitor is complete -
      Atmospheric pressure difference between sequence 1 and 8 0.3 kPa (2.25 mmHg) or less