Inspection Procedure
- PERFORM ACTIVE TEST BY INTELLIGENT TESTER
- Connect the intelligent tester to the DLC3.
- Turn the engine switch on (IG).
- Turn the intelligent tester main switch on.
- Select the item below in the ACTIVE TEST and then check the front fog light operation.
ACTIVE TEST: BODY NO. 5 (Front Controller)
ACTIVE TESTItem Test Details Diagnostic Note F FOG LIGHT RLY Front fog light relay ON / OFF - OK: Fog light illuminates.
NG: Go to step 2
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
- INSPECT FUSE (FR FOG)
- Remove the FR FOG fuse from the engine room No. 2 relay block.
- Measure the resistance of the fuse.
Standard resistance: Below 1 Ω
NG: REPLACE FUSE
OK: Go to Next Step
- CHECK HARNESS AND CONNECTOR (ENGINE ROOM NO. 2 RELAY BLOCK - BATTERY)
- Disconnect the 2E relay block connector.
- Measure the voltage according to the value (s) in the table below.
Standard voltage
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 2E-1 - Body ground Always 10 to 14 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to Next Step
- CHECK HARNESS AND CONNECTOR (ENGINE ROOM NO. 2 R/B - FOG LIGHT)
- Check the wire harness between the fog light (front LH) and engine room No. 2 relay block, and the fog light (front LH) and body ground.
- Disconnect the 2G relay block connector.
- Disconnect the B13 fog light connector.
- Measure the resistance according to the value (s) in the table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 2G-7 - B13-2 (HI) Always Below 1 Ω 26-7 or B13-2 (HI) - Body ground Always 10 kΩ or higher B13-1 (E) - Body ground Always Below 1 Ω
- Check the wire harness between the fog light (front RH) and engine room No. 2 relay block, and the fog light (front RH) and body ground.
- Disconnect the 2G relay block connector.
- Disconnect the B1 fog light connector.
- Measure the resistance according to the value (s) in the table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 2G-6 - B1-2 (HI) Always Below 1 Ω 2G-6 or B1-2 (HI) - Body ground Always 10 kΩ or higher B1-1 (E) - Body ground Always Below 1 Ω
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE ENGINE ROOM NO. 2 R/B (FRONT CONTROLLER)
- Check the wire harness between the fog light (front LH) and engine room No. 2 relay block, and the fog light (front LH) and body ground.