Test Item
WARNING: This page is about a different car, the 2009 Nissan Maxima. However, it is still accessible from the selected car via links, so may be relevant.
SOLENOID VALVE
- When performing an active test of the ABS function, select "MAIN SIGNALS" for each test item.
- For ABS solenoid valve, touch "Up", "Keep", and "Down" on the display screen. For ABS solenoid valve (ACT), touch "Up", "ACT UP", "ACT KEEP" and confirm that solenoid valves operate as shown in the table below.
SOLENOID VALVES OPERATION CHART
| Operation | ABS solenoid valve | ABS solenoid valve (ACT) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Up | Keep | Down | Up | ACT UP | ACT KEEP | ||||
| FR RH SOL | FR RH IN SOL | Off | On | On | - | - | - | ||
| FR RH OUT SOL | Off | Off | On(1) | - | - | - | |||
| USV [FR-RR] | Off | Off | On(1) | - | - | - | |||
| USV [FR-RL] | Off | Off | On(1) | - | - | - | |||
| HSV [FL-RR] | Off | Off | On(1) | - | - | - | |||
| HSV [FR-RL] | Off | Off | On(1) | - | - | - | |||
| FR LH SOL | FR LH IN SOL | Off | On | On | - | - | - | ||
| FR LH OUT SOL | Off | Off | On(1) | - | - | - | |||
| USV [FR-RR] | Off | Off | On(1) | - | - | - | |||
| USV [FR-RL] | Off | Off | On(1) | - | - | - | |||
| HSV [FL-RR] | Off | Off | On(1) | - | - | - | |||
| HSV [FR-RL] | Off | Off | On(1) | - | - | - | |||
| RR RH SOL | RR RH IN SOL | Off | On | On | - | - | - | ||
| RR RH OUT SOL | Off | Off | On(1) | - | - | - | |||
| USV [FR-RR] | Off | Off | On(1) | - | - | - | |||
| USV [FR-RL] | Off | Off | On(1) | - | - | - | |||
| HSV [FL-RR] | Off | Off | On(1) | - | - | - | |||
| HSV [FR-RL] | Off | Off | On(1) | - | - | - | |||
| RR LH SOL | RR LH IN SOL | Off | On | On | - | - | - | ||
| RR LH OUT SOL | Off | Off | On(1) | - | - | - | |||
| USV [FR-RR] | Off | Off | On(1) | - | - | - | |||
| USV [FR-RL] | Off | Off | On(1) | - | - | - | |||
| HSV [FL-RR] | Off | Off | On(1) | - | - | - | |||
| HSV [FR-RL] | Off | Off | On(1) | - | - | - | |||
| FR RH ABS SOLENOID (ACT) | FR RH IN SOL | - | - | - | Off | Off | Off | ||
| FR RH OUT SOL | - | - | - | Off | Off | Off | |||
| USV [FR-RR] | - | - | - | Off | Off | Off | |||
| USV [FR-RL] | - | - | - | Off | On | On | |||
| HSV [FL-RR] | - | - | - | Off | Off | Off | |||
| HSV [FR-RL] | - | - | - | Off | On(1) | Off | |||
| FR LH ABS SOLENOID (ACT) | FR LH IN SOL | - | - | - | Off | Off | Off | ||
| FR LH OUT SOL | - | - | - | Off | Off | Off | |||
| USV [FR-RR] | - | - | - | Off | Off | Off | |||
| USV [FR-RL] | - | - | - | Off | On | On | |||
| HSV [FL-RR] | - | - | - | Off | Off | Off | |||
| HSV [FR-RL] | - | - | - | Off | On(1) | Off | |||
| RR RH ABS SOLENOID (ACT) | RR RH IN SOL | - | - | - | Off | Off | Off | ||
| RR RH OUT SOL | - | - | - | Off | Off | Off | |||
| USV [FR-RR] | - | - | - | Off | Off | Off | |||
| USV [FR-RL] | - | - | - | Off | On | On | |||
| HSV [FL-RR] | - | - | - | Off | Off | Off | |||
| HSV [FR-RL] | - | - | - | Off | On(1) | Off | |||
| RR LH ABS SOLENOID (ACT) | RR LH IN SOL | - | - | - | Off | Off | Off | ||
| RR LH OUT SOL | - | - | - | Off | Off | Off | |||
| USV [FR-RR] | - | - | - | Off | Off | Off | |||
| USV [FR-RL] | - | - | - | Off | On | On | |||
| HSV [FL-RR] | - | - | - | Off | Off | Off | |||
| HSV [FR-RL] | - | - | - | Off | On(1) | Off | |||
|
|||||||||
ABS MOTOR
- Touch "On" and "Off" on screen. Make sure motor relay, actuator relay, V/R output and M/R output operate as shown in table below.
ABS MOTOR OPERATION CHART
| Operation | On | Off |
|---|---|---|
| MOTOR RELAY | On | Off |
| ACTUATOR RLY | On | On |
| V/R OUTPUT | On | On |
| M/R OUTPUT | On | Off |