Detailed Flow
- CHECK ENGINE START
Crank the engine and check that the engine starts.
Does the engine start?
YES >> GO TO 2.
NO >> GO TO 3.
- CHECK THAT THE STARTER MOTOR STOPS
Check that the starter motor stops after starting the engine.
Does the starter motor stop?
YES >> Inspection End.
NO >> Replace starter motor. Refer to REMOVAL AND INSTALLATION
- CHECK THAT THE ENGINE TURNS WHEN CRANKING
Check that the engine turns when cranking.
Does engine turn when cranking?
YES >> GO TO 4.
NO >> GO TO 5.
- CHECK THE ENGINE SPEED WHEN CRANKING
Check that the engine speed is not low when cranking.
Does engine turn normally?
YES >> Check ignition/fuel system.
NO >> Check charge condition, corrosion and connection condition of the battery. Refer to HOW TO HANDLE BATTERY
- CHECK STARTER MOTOR ACTIVATION
Check that the starter motor runs at cranking.
Does starter motor turn?
YES >> Replace starter motor. Refer to REMOVAL AND INSTALLATION
NO >> GO TO 6.
- CHECK POWER SUPPLY CIRCUIT
- Fuse and fusible link
- Charge condition, corrosion and connection of the battery.
Check the following conditions:
Are these inspection results normal?
YES >> GO TO 7.
NO >> Repair as needed.
- CHECK STARTING SYSTEM WIRING
- "B" terminal circuit. Refer to Diagnosis Procedure - VQ40DE or Diagnosis Procedure - VK56DE
- "S" terminal circuit. Refer to Diagnosis Procedure - VQ40DE or Diagnosis Procedure - VK56DE
Check the following:
Are the inspection results normal?
YES >> Replace starter motor. Refer to REMOVAL AND INSTALLATION .
NO >> Repair as needed.