System Operation

WARNING: This page is about a different car, the 2009 Nissan Maxima. However, it is still accessible from the selected car via links, so may be relevant.

System Operation

Fig 1: Blower Motor Circuit
G05875909Courtesy of NISSAN MOTOR CO., U.S.A.

Normal Automatic Airflow Control

Fan Speed Control Specification

Fig 2: Fan Speed Control Graph
G05887021Courtesy of NISSAN MOTOR CO., U.S.A.

Starting Airflow Control

Starting Fan Speed Control

Start-up from COLD SOAK Condition (Automatic mode)

In cold start-up condition, where the engine coolant temperature is below 56°C (133°F), the blower does not operate for a short period of time (up to 150 seconds). The exact start delay time varies depending on the ambient temperature and engine coolant temperature.

In the most extreme case (very low ambient temperature) the blower start delay is 150 seconds, as described above. After this delay, the blower will operate at low speed until the engine coolant temperature rises above 56°C (133°F), and then the fan speed increases to the objective speed.

Start-up from usual or HOT SOAK Condition (Automatic mode)

The blower will begin operation momentarily after the AUTO switch is pressed. The fan speed rises gradually to the objective speed over a time period of 3 seconds or less (actual time depends on the objective fan speed).