LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2007 >> LS 460L >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning >> Air Conditioning System >> Customize Parameters
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Customize Parameters

  1. CUSTOMIZING FUNCTION WITH INTELLIGENT TESTER OR TECHSTREAM (REFERENCE) 
    NOTE:
    • When the customer requests a change in a function, first make sure that the function can be customized.
    • Be sure to make a note of the current settings before customizing.
    • When troubleshooting a function, first make sure that the function is set to the default setting.
    1. Connect the intelligent tester or Techstream to the DLC3.
    2. Turn the engine switch on (IG).
    3. Turn the tester on.
    4. Enter the following menus:
      1. Intelligent tester - Select: CUSTOMIZE /
      2. Techstream - Select: Customize Setting /
    5. Select the setting by referring to the table below.
      1. Intelligent tester

        AIR CONDITIONER 

        INTELLIGENT TESTER - AIR CONDITIONER REFERENCE CHART

        Display Default Contents Setting
        SET TEMP SHIFT NORMAL To control with the shifted temperature against the display temperature +2 C / +1 C / NORMAL / -1 C / -2 C
        AIR INLET MODE AUTO In case of turning the A/C ON when you desire to make the compartment cool down quickly, this is the function to change the mode automatically to RECIRCULATION mode MANUAL/AUTO
        COMPRESSOR MODE AUTO Function to turn the A/C ON automatically by pressing the AUTO button when the blower is ON and the A/C is OFF MANUAL/AUTO
        COMPRS/DEF OPER LINK Function to turn the A/C ON automatically linked with the FRONT DEF button when A/C is OFF NORMAL / LINK
        EVAP CTRL AUTO Function to set the evaporator control to the AUTOMATIC position (AUTO) to save power, or to the coldest position (MANUAL) to dehumidify the air and to prevent the windows from fogging up MANUAL/AUTO
        GAS SENS SHIFT NORMAL Function to change the sensitivity of the exhaust gas sensor MU MORE / MORE / LI MORE / NORMAL / LI LESS / LESS / MU LESS
        BUTTON PRS BUZ ON Function to sound a buzzer when button is pressed OFF / ON
        FOOT/DEF MODE ON Function to turn the airflow from FOOT / DEF ON automatically when AUTO MODE is ON OFF / ON
        AUTO BLOW UP ON Function to change the blower level automatically when the defroster is ON OFF / ON
        FILTER SENS NORMAL Function to change the sensitivity of the air conditioning filter clogging sensor LESS/NORMAL / MORE
        AMBIENT TMP SFT NORMAL Function to control the shifted ambient temperature in relation to the displayed ambient temperature +3 C / +2 C / +1 C / NORMAL / -1 C/-2 C/-3 C
      2. Techstream

        Air Conditioner 

        TECHSTREAM - AIR CONDITIONER REFERENCE CHART

        Display Default Contents Setting
        Set Temperature Shift Normal To control with the shifted temperature against the display temperature +2 C / +1 C / Normal / -1 C / -2 C
        Air Inlet Mode Automatic In case of turning the A/C ON when you desire to make the compartment cool down quickly, this is the function to change the mode automatically to RECIRCULATION mode Manual / Automatic
        Compressor Mode Automatic Function to turn the A/C ON automatically by pressing the AUTO button when the blower is ON and the A/C is OFF Manual / Automatic
        Compressor/Air Inlet DEF operation Link Function to turn the A/C ON automatically linked with the FRONT DEF button when A/C is OFF Normal / Link
        Evaporator Control Automatic Function to set the evaporator control to the AUTOMATIC position (Automatic) to save power, or to the coldest position (Manual) to dehumidify the air and to prevent the windows from fogging up Manual / Automatic
        Emission Gas Sensor Shift Normal Function to change the sensitivity of the exhaust gas sensor Much More / More / Little More / Normal / Little Less / Less / Much Less
        Button Press Buzzer ON Function to sound a buzzer when button is pressed OFF / ON
        Foot/DEF Auto Mode ON Function to turn the airflow from FOOT / DEF ON automatically when AUTO MODE is ON OFF / ON
        Foot/DEF Automatic Blow Up Function ON Function to change the blower level automatically when the defroster is ON OFF / ON
        Filter Sensor Normal Function to change the sensitivity of the air conditioning filter clogging sensor Less / Normal / More
        Ambient Temperature Shift Normal Function to control the shifted ambient temperature in relation to the displayed ambient temperature +3C/+2C/+1 C/Normal/-1 C / -2 C / -3 C