Customize Parameters
- CUSTOMIZING FUNCTION WITH INTELLIGENT TESTER OR TECHSTREAM (REFERENCE) NOTE:
- When the customer requests a change in a function, first make sure that the function can be customized.
- Be sure to make a note of the current settings before customizing.
- When troubleshooting a function, first make sure that the function is set to the default setting.
- Connect the intelligent tester or Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the tester on.
- Enter the following menus:
- Intelligent tester - Select: CUSTOMIZE /
- Techstream - Select: Customize Setting /
- Select the setting by referring to the table below.
- Intelligent tester
AIR CONDITIONER
INTELLIGENT TESTER - AIR CONDITIONER REFERENCE CHARTDisplay Default Contents Setting SET TEMP SHIFT NORMAL To control with the shifted temperature against the display temperature +2 C / +1 C / NORMAL / -1 C / -2 C AIR INLET MODE AUTO In case of turning the A/C ON when you desire to make the compartment cool down quickly, this is the function to change the mode automatically to RECIRCULATION mode MANUAL/AUTO COMPRESSOR MODE AUTO Function to turn the A/C ON automatically by pressing the AUTO button when the blower is ON and the A/C is OFF MANUAL/AUTO COMPRS/DEF OPER LINK Function to turn the A/C ON automatically linked with the FRONT DEF button when A/C is OFF NORMAL / LINK EVAP CTRL AUTO Function to set the evaporator control to the AUTOMATIC position (AUTO) to save power, or to the coldest position (MANUAL) to dehumidify the air and to prevent the windows from fogging up MANUAL/AUTO GAS SENS SHIFT NORMAL Function to change the sensitivity of the exhaust gas sensor MU MORE / MORE / LI MORE / NORMAL / LI LESS / LESS / MU LESS BUTTON PRS BUZ ON Function to sound a buzzer when button is pressed OFF / ON FOOT/DEF MODE ON Function to turn the airflow from FOOT / DEF ON automatically when AUTO MODE is ON OFF / ON AUTO BLOW UP ON Function to change the blower level automatically when the defroster is ON OFF / ON FILTER SENS NORMAL Function to change the sensitivity of the air conditioning filter clogging sensor LESS/NORMAL / MORE AMBIENT TMP SFT NORMAL Function to control the shifted ambient temperature in relation to the displayed ambient temperature +3 C / +2 C / +1 C / NORMAL / -1 C/-2 C/-3 C - Techstream
Air Conditioner
TECHSTREAM - AIR CONDITIONER REFERENCE CHARTDisplay Default Contents Setting Set Temperature Shift Normal To control with the shifted temperature against the display temperature +2 C / +1 C / Normal / -1 C / -2 C Air Inlet Mode Automatic In case of turning the A/C ON when you desire to make the compartment cool down quickly, this is the function to change the mode automatically to RECIRCULATION mode Manual / Automatic Compressor Mode Automatic Function to turn the A/C ON automatically by pressing the AUTO button when the blower is ON and the A/C is OFF Manual / Automatic Compressor/Air Inlet DEF operation Link Function to turn the A/C ON automatically linked with the FRONT DEF button when A/C is OFF Normal / Link Evaporator Control Automatic Function to set the evaporator control to the AUTOMATIC position (Automatic) to save power, or to the coldest position (Manual) to dehumidify the air and to prevent the windows from fogging up Manual / Automatic Emission Gas Sensor Shift Normal Function to change the sensitivity of the exhaust gas sensor Much More / More / Little More / Normal / Little Less / Less / Much Less Button Press Buzzer ON Function to sound a buzzer when button is pressed OFF / ON Foot/DEF Auto Mode ON Function to turn the airflow from FOOT / DEF ON automatically when AUTO MODE is ON OFF / ON Foot/DEF Automatic Blow Up Function ON Function to change the blower level automatically when the defroster is ON OFF / ON Filter Sensor Normal Function to change the sensitivity of the air conditioning filter clogging sensor Less / Normal / More Ambient Temperature Shift Normal Function to control the shifted ambient temperature in relation to the displayed ambient temperature +3C/+2C/+1 C/Normal/-1 C / -2 C / -3 C
- Intelligent tester