| TRQ1 |
Torque sensor 1 rotation angle/ Min.: 0 deg, Max.: 360 deg |
Steering wheel is turned |
Value changes from 0 to 360° every 45° of steering angle |
| TRQ2 |
Torque sensor 2 rotation angle/ Min.: 0 deg, Max.: 360 deg |
Steering wheel is turned |
Value changes from 0 to 360° every 45° of steering angle |
| SPD |
Vehicle speed from meter/Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) |
- Vehicle is stopped
- Vehicle is driven at a constant speed
|
- 0 km/h (0 mph)
- No significant fluctuation
|
| ENGINE REV |
Engine revolution/Min.: 0 rpm, Max.: 8192 rpm |
Engine is running at a constant speed |
No significant fluctuation |
| MOTOR ACTUAL |
Amount of current to motor/Min.: -128 A, Max.: 127 A |
Power steering is in operation |
Value changes in proportion to steering effort |
| COMMAND VALUE |
Demanded amount of current to motor/Min.: -128 A, Max.: 127 A |
Power steering is in operation |
Value changes in proportion to steering effort |
| STR ANGL VEL |
Steering angle speed/Min.: -4096 deg/sec, Max.: 4064 deg/sec |
Steering wheel is turned |
Value changes in proportion to steering speed |
| THERMISTOR TEMP |
ECU substrate temperature/ Min.: -50°C, Max.: 205°C |
IG switch ON |
- |
| PIG SUPPLY |
Power source voltage to activate motor/Min.: 0 V, Max.: 25.5 V |
Power steering is in operation |
10 to 14 V |
| IG SUPPLY |
ECU power source voltage/Min.: 0 V, Max.: 25.5 V |
IG switch ON |
10 to 14 V |
| TRQ1 ZERO VAL |
Zero point value of torque sensor 1/Min.: 0 deg, Max.: 360 deg |
Steering wheel is not turned (without load) |
Values differ depending on vehicle |
| TRQ2 ZERO VAL |
Zero point value of torque sensor 2/Min.: 0 deg, Max.: 360 deg |
Steering wheel is not turned (without load) |
Values differ depending on vehicle |
| STEERING TORQUE |
Steering torque/Min.: -7.0 N*m, Max.: 7.0 N*m |
Steering wheel is turned |
Value changes in proportion to steering effort |
| MOTOR ROTATE |
Motor rotation angle/Min.: 0 deg, Max.: 360 deg |
Steering wheel is turned |
Value changes from 0 to 360° every 45° of steering angle |
| COMMAND VALUE 2 |
Demanded amount of current to motor 2/Min.: -128 A, Max.: 127 A |
- |
- |
| MOTOR VOLTAGE |
Motor power source voltage/Min.: 0 V, Max.: 64 V |
Power steering is in operation |
42 to 51 V |
| MTR TERMINAL (U) |
Motor terminal voltage (U phase)/ Min.: 0 V, Max.: 64 V |
Power steering is in operation |
2 to 51 V |
| MTR TERMINAL (V) |
Motor terminal voltage (V phase)/ Min.: 0 V, Max.: 64 V |
Power steering is in operation |
2 to 51 V |
| MTR TERMINAL (W) |
Motor terminal voltage (W phase)/ Min.: 0 V, Max.: 64 V |
Power steering is in operation |
2 to 51 V |
| BATTERY VOLTAGE |
Battery voltage/Min.: 0 V, Max.: 25 V |
IG switch ON |
10 to 14 V |
| DRDD VOLTAGE |
Power source voltage to power steering converter/Min.: 0 V, Max.: 25 V |
IG switch ON |
10 to 14 V |
| HV BAT VOLTAGE |
HV battery voltage/Min.: 0 V, Max.: 510 V |
IG switch ON |
150 to 430 V |
| POWER OK SIG |
Power source OK signal/OK or NG |
IG switch ON |
OK |
| BREAK GATE REQ |
Break gate request signal/OK or Break |
IG switch ON |
OK |
| DC-DC WARNING |
Power steering converter warning signal/OK, NG(1), NG (2) or STOP() |
IG switch ON |
OK |
| PS ASSIST SIG |
Power steering assist signal/ON or OFF |
IG switch ON |
OK |
| MTR OVERHEAT |
Continuous overheat prevention control record/REC or UNREC |
- |
- |
| MTR LOW POWER |
PIG power source voltage drop record/REC or UNREC |
- |
- |
| ENG REV INTER |
Record of engine revolution signal interruption/REC or UNREC |
- |
- |
| STR ANGL INTER |
Record of steering angle sensor signal interruption/REC or UNREC |
- |
- |
| SPD SIG INVALID |
Record of vehicle speed signal invalid/REC or UNREC |
- |
- |
| CONTROL MODE |
Codes indicating DTC detection timing during ECU control are displayed in hexadecimal |
- |
- |
| TEST MODE STAT |
Selected mode/NORMAL or TEST |
- |
- |
| READY STATUS |
Ready status/OFF or READY |
- |
- |