  1. DATA LIST FOR OCCUPANT CLASSIFICATION ECU 

    HINT:

    Using the intelligent tester to read the DATA LIST allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the DATA LIST information early in troubleshooting is one way to save diagnostic time.

    NOTE: In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
    1. Warm up the engine.
    2. Turn the ignition switch OFF.
    3. Connect the intelligent tester or the OBD II scan tool to the DLC3.
    4. Turn the ignition switch ON.
    5. Turn ON the intelligent tester.
    6. Enter the following menus: DIAGNOSIS / OBD/ MOBD / OCCUPANT DETECTION
    7. According to the display on tester, read the "DATA LIST".

      Occupant classification ECU: 

      DATA LIST CHART

      Tester Display Measurement Item/ Range Normal Condition Specified Condition for Zero Point Calibration Diagnostic Note
      PASSENGER CLASS Passenger classification / NG, AM50, AF05, CHILD or OFF NG: Data is not determined
      AM50: Adult is seated and seat is in rear position
      AF05: Adult is seated and seat is in front position
      CHILD: Child is seated OFF: Vacant
      OFF -
      P BUCKLE SW Buckle switch (passenger side)/SET, UNSET or NG SET: Passenger side seat belt is fastened
      UNSET: Passenger side seat belt is unfastened
      NG: Data is not determined
      UNSET -
      RELATIVE PRESS Pressure sensor output / Min.: 0, Max.: 255 0 to 210 (reference value) 0 to 2 -
      FILTERED PRESS Filtered pressure sensor output/Min.: 0, Max.: 255 38 to 240 38 to 75 If value is outside range of Specified Condition for Zero Point Calibration, check whether any objects placed on seat cushion and that seat cushion fitted correctly
      THERMISTOR TEMP Thermistor temperature output/Min.:-40°C (-40°F), Max.: 90°C (194°F) -40 to 85°C (-40 to 185°F) 3 to 40°C (36 to 104°F) If value is outside range of Specified Condition for Zero Point Calibration, adjust temperature to proper range by using air conditioner, etc.
      WEIGHT THRESH Weight threshold / Min.: 0, Max.: 255 36 to 67 (reference value) 36 to 67 (reference value) -
      FILTERED TENSION Filtered belt tension output /Min.: 0, Max.: 255 39 to 229 39 to 64 (no load) -
      EMPTY THRESH Empty threshold value from seat factory / Min.: 0, Max.: 255 38 to 75 38 to 75 -
      ALLOW THRESH Threshold value for adult passenger or not from seat factory / Min.: 0, Max.: 255 43 to 64 (reference value) 43 to 64 (reference value) -
      #PRESENT CODES Number of present trouble codes / Min.: 0, Max.: 255 0 0 -
      #PAST CODES Number of past trouble codes/Min.: 0, Max.: 255 0 0 -