LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mazda >> 2000 >> MPV ES >> Repair and Diagnosis >> External Pages >> Different car >> Section 521 (Symptom Troubleshooting [Engine Control System BP, BP With TC)) >> Engine Control System Operation Inspection >> Variable Valve Timing System Operation Inspection >> When idling cannot be continued
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

When idling cannot be continued

WARNING: This page is about a different car, the 2005 Mazda MX-5 Miata. However, it is still accessible from the selected car via links, so may be relevant.
  1. Remove the OCV (oil control valve) and verify that the spool valve is at maximum retard position.
    • If the spool valve is stuck in advance direction, replace the OCV (oil control valve).
  2. Connect the OCV (oil control valve) connector.
  3. Turn the ignition switch on.
  4. Verify that the spool valve is at maximum retard position.
    • If the spool valve is stuck in advance direction, inspect for the following.
      • Short circuit in harnesses or connectors between the OCV (oil control valve) and the PCM.
  5. Inspect the VVT (variable valve timing) actuator.