October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
4WABS Control Module Removal/Installation
- Disconnect the negative battery cable.
- Remove the three hydraulic unit mounting bolts.
- Tightening Torque
- 7-9 N.m (71-92 kgf.cm, 63-79 in.lbf)
- Disconnect the two electrical connectors.
- Remove the 4 bolts and control module.
- Tightening Torque
- 1-2 N.m (10.2-20 kgf.cm, 9-17 in.lbf)
- Install in reverse order of removal.
Courtesy of MAZDA MOTORS CORP.
- Reprogram 4WABS control module. See 4WABS CONTROL MODULE REPROGRAMMING .