Possible Cause
- Trunk Lid opener switch malfunction
- Open circuit in wiring harness between the following terminals:
- Rear body control module (RBCM) terminal 4M and trunk lid opener switch terminal C
- LF control unit terminal C and request switch (LF) terminal D
- LF control unit terminal A and request switch (RF) terminal D
- Start stop unit terminal 1P and door lock link switch (driver's side) terminal D
- Start stop unit terminal 1AF and ground
- Start stop unit terminal 2B and ground
- Short to ground in wiring harness between start stop unit terminal 1P and door lock link switch (driver's side) terminal D
- Connector poor contact or terminal damage
- Customer's mis-operation or misunderstanding
- Effect of non-standard equipment (any control unit with built-in micro computer such as radio set, mobile telephone, and TV)