Inspection Procedure E-1: Keyless Entry System: Keyless Entry System Does Not Operate: Diagnosis
Required Special Tools:
- MB991223: Harness Set
- MB992006: Extra Fine Probe
- MB991958: Scan Tool (M.U.T.-III Sub Assembly)
- MB991824: V.C.I.
- MB991827: M.U.T.-III USB Cable
- MB991910: M.U.T.-III Main Harness A
- STEP 1. Verify the central door locking system.
Q: Does the central door locking system work normally?
YES: Go to Step 2.
NO: Refer to INSPECTION PROCEDURE C-1 "THE CENTRAL DOOR LOCKING SYSTEM DOES NOT WORK AT ALL ."
- STEP 2. Check the input signal (by using the pulse check mode of the monitor).
Check input signals from the transmitter.
CAUTION: To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool MB991958.- Connect scan tool MB991958.Refer to "HOW TO CONNECT SWS MONITOR ."
- Operate scan tool MB991958 according to the procedure below to display "Pulse check."
- Select "Interactive Diagnosis."
- Select "System select."
- Select "SWS."
- Select "Pulse Checking."
- Push the transmitter "LOCK" or "UNLOCK" button.
- Check that scan tool MB991958 sounds
Q: When the transmitter "LOCK" or "UNLOCK" button is turned ON, does scan tool MB991958 sound?
YES: Replace the ETACS-ECU. When the ETACS-ECU is replaced, register the encrypted code. Refer to ENCRYPTED CODE REGISTRATION CRITERIA TABLE . All the doors can be locked or unlocked by means of the transmitter.
NO: Refer to INSPECTION PROCEDURE N-8 "ETACS-ECU DOES NOT RECEIVE ANY SIGNAL FROM THE LOCK, UNLOCK, TRUNK OR PANIC SWITCH ."