DIAGNOSTIC ITEM 30: Diagnose When The Scan Tool (M.U.T.-IIISE) Cannot Receive The Data Sent By Combination Meter: Diagnosis
Required Special Tools:
- MB991223: Harness Set
- MB992006: Extra Fine Probe
- STEP 1. Connector check: joint connector (CAN5) and combination meter connector CAUTION: The strand end of the twist wire should be within 10 cm (3.9 inches) from the connector. For details refer to TEST EQUIPMENT .
When checking the joint connector, ensure that its wiring harness side and its short pins are not damaged.
Q: Is the check result normal?
YES: Go to Step 2.
NO: Repair the defective connector. Replace the joint connector as necessary.
- STEP 2. Resistance measurement at joint connector (CAN5) and combination meter connector. CAUTION: A digital multimeter should be used. For details refer to TEST EQUIPMENT .CAUTION: The test wiring harness should be used. For details refer to TEST EQUIPMENT .
- Disconnect joint connector (CAN5) and the combination meter connector, and measure at the wiring harness side.
- Turn the ignition switch to the "LOCK" (OFF) position.CAUTION: When measuring the resistance, disconnect the negative battery terminal. For details refer to TEST EQUIPMENT .
- Ensure that the negative battery terminal is disconnected.
- Continuity between joint connector (CAN5) terminal No. 10 and combination meter connector terminal No. 14
OK: The resistance should be 2 ohms or less
- Continuity between joint connector (CAN5) terminal No. 21 and combination meter connector terminal No. 15
OK: The resistance should be 2 ohms or less
CAUTION: Strictly observe the specified wiring harness repair procedure. For details refer to TEST EQUIPMENT .Q: Is the check result normal?
YES: <All the resistances measure 2 ohms or less> Go to Step 3.
NO: <Either or all of the resistances measure more than 2 ohms> Repair the wiring harness between joint connector (CAN5) and the combination meter.
- STEP 3. Resistance measurement at combination meter connector. CAUTION: A digital multimeter should be used. For details refer to TEST EQUIPMENT .
- Remove the combination meter, and measure at the equipment side.
- Resistance between combination meter connector terminal Nos.14 and 15
OK: 120 ± 20 ohms
CAUTION: Strictly observe the specified wiring harness repair procedure. For details refer to TEST EQUIPMENT .Q: Is the check result normal?
YES: <Within 120 ± 20 ohms> Power supply to the combination meter may be suspected. Diagnose the combination meter. Refer to SYMPTOM CHART .
NO: <Not within 120 ± 20 ohms> Replace the combination meter.