Initialization Procedure
Required Special Tools:
- MB992744: Vehicle Communication Interface-Lite (V.C.I.-Lite)
- MB992745: V.C.I.-Lite Main Harness A
- MB992747: V.C.I.-Lite USB Cable Short
- MB992748: V.C.I.-Lite USB Cable Long
CAUTION:
To prevent damage to the scan tool (M.U.T.-IIISE), always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the scan tool (M.U.T.-IIISE).
- After the ignition switch is in "LOCK" (OFF) position, connect scan tool (M.U.T.-IIISE) to the data link connector.
- Turn the ignition switch to the "ON" position.
- Select "MFI" from System select Screen of the scan tool (M.U.T.-IIISE).
- Select "Special Function" from MFI Screen.
- Select "Learned value reset" from Special Function Screen.
- Select "All learned value" from Learned value reset Screen.
- Initialize the learning value by pressing the "OK" button.
- After initializing the learning value, the learning value of DFI and MFI engine idling is necessary. Refer to ENGINE IDLING LEARNING PROCEDURE .