| Manual valve |
Distributes the clutch operating pressure to each circuit, depending on each selector lever position. |
| Lock-up control valve |
Regulates the engagement pressure and disengagement pressure of the torque converter. |
| Torque converter regulator valve |
Regulates the supply pressure to the torque converter to the optimal pressure for the driving conditions. |
| Pressure regulator valve |
Regulates the discharge pressure from the oil pump to the optimal pressure (line pressure) for the driving conditions. |
| Secondary reducing valve |
Reduces the line pressure to regulate the secondary pressure. |
| Primary reducing valve |
Reduces the line pressure to regulate the primary pressure. |
| Pilot valve A |
Reduces the line pressure to regulate the operation pressures of the solenoid valves below.
- Primary pressure solenoid valve
- Secondary pressure solenoid valve
- Line pressure solenoid valve
- Select solenoid valve
|
| Pilot valve B |
Reduces fluid pressure delivered from pilot valve A to regulate the operation pressure of the lock-up solenoid valve. |
| Line pressure solenoid valve |
Controls the pressure regulator valve. |
| Primary pressure solenoid valve |
Controls the primary reducing valve. |
| Secondary pressure solenoid valve |
Controls the secondary reducing valve. |
| Lock-up solenoid valve |
Controls the lock-up control valve. |
| Select solenoid valve |
Regulates the forward clutch pressure and reverse brake pressure. |