Diagnostic Trouble Code Set Conditions
These DTCs are stored in the following cases:
DTC C1511: Torque sensor main system malfunction
- The torque sensor main output voltage does not agree with the predetermined voltage stored in the microcomputer, and the microcomputer determines that a problem has occurred in the torque sensor main system.
DTC C1512: Torque sensor sub system malfunction
- The torque sensor sub output voltage does not agree with the predetermined voltage stored in the microcomputer, and the microcomputer determines that a problem has occurred in the torque sensor sub system.