Logic Flow Chart <DTC P1D05>
Check Conditions <DTC P1D05>
- Charge permission from PHEV-ECU is on.
- Charger capacitor voltage is more than 240 volts (200 volts input) or 120 volts (100 voltage input).
Judgment Criterion <DTC P1D05>
When the difference between the value of input actual current and the value of input target current remains at 2 amperes or more for 10 seconds