Component Function Check
When S-MODE switch is pressed (less than 1 second), S-MODE indicator illuminates, combination meter sends S-MODE switch signal to ECM via the CAN communication, and then SynchroRev Match mode (SMODE) is activated. When S-MODE is pressed and held (1 second or more), S-MODE indicator turns OFF and S-MODE is cancelled, and then returns to normal M/T.
- CHECK S-MODE SWITCH FUNCTION-I NOTE: If DTC UXXXX are displayed, first perform the trouble diagnosis for DTC UXXXX.
- Turn ignition switch ON.
- Select "M/T SYNCHRO SW" in "DATA MONITOR" mode with CONSULT.
- Check "M/T SYNCHRO SW" indication under the following conditions.
Monitor item
Condition
Indication
M/T SYNCHRO SW
S-MODE switch
Pressed
ON
Released
OFF
Is the inspection result normal?
YES
GO TO 2.
NO
Refer to Diagnosis Procedure .
- CHECK S-MODE SWITCH FUNCTION-II
Check the S-MODE indicator under the following condition.
Condition
S-MODE indicator
S-MODE switch
Press (less than 1 second)
Illuminated
Press (1 second or more)
Not illuminated
Is the inspection result normal?
YES
INSPECTION END
NO
Refer to Diagnosis Procedure .