LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Nissan-Datsun >> 2020 >> Leaf SL Plus >> Repair and Diagnosis >> Body & Frame >> Windows >> Power Window Control System (Diagnostics) >> Component Parts /Circuit Diagnosis >> Encoder Circuit >> Diagnosis Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Diagnosis Procedure

  1. CHECK ENCODER PULSE SIGNAL 
    1. Turn power switch ON.
    2. Check signal between main power window and door lock/unlock switch harness connector and ground with oscilloscope.

      (+)

      (-)

      Signal

      (Reference value)

      Main power window and door lock/unlock switch

      Connector

      Terminal

      D35

      4

      Ground

      Refer to following signal

      5

      G06934392Courtesy of NISSAN NORTH AMERICA, INC.

    Is the inspection result normal?

    YES

    GO TO 7.

    NO

    GO TO 2.

  2. CHECK ENCODER SIGNAL CIRCUIT 
    1. Turn power switch OFF.
    2. Disconnect main power window and door lock/unlock switch connector and front power window motor LH connector.
    3. Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.

      Main power window and door lock/unlock switch

      Front power window motor LH

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      D35

      4

      D37

      5

      Yes

      5

      6

    4. Check continuity between main power window and door lock/unlock switch harness connector and ground.

      Main power window and door lock/unlock switch

      Ground

      Continuity

      Connector

      Terminal

      D35

      4

      No

      5

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    Repair or replace harness.

  3. CHECK ENCODER POWER SUPPLY 
    1. Connect main power window and door lock/unlock switch connector.
    2. Turn power switch ON.
    3. Check voltage between front power window motor LH harness connector and ground.

      (+)

      (-)

      Voltage

      (Approx.)

      Front power window motor LH

      Connector

      Terminal

      D37

      2

      Ground

      Battery voltage

    Is the inspection result normal?

    YES

    GO TO 5.

    NO

    GO TO 4.

  4. CHECK ENCODER POWER SUPPLY CIRCUIT 
    1. Turn power switch OFF.
    2. Disconnect main power window and door lock/unlock switch connector.
    3. Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.

      Main power window and door lock/unlock switch

      Front power window motor LH

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      D35

      14

      D37

      2

      Yes

    4. Check continuity between main power window and door lock/unlock switch harness connector and ground.

      Main power window and door lock/unlock switch

      Ground

      Continuity

      Connector

      Terminal

      D35

      14

      No

    Is the inspection result normal?

    YES

    Replace main power window and door lock/unlock switch. Refer to POWER WINDOW MAIN SWITCH : Removal & Installation .

    NO

    Repair or replace harness.

  5. CHECK ENCODER GROUND CIRCUIT 
    1. Turn power switch OFF.
    2. Check continuity between front power window motor LH harness connector and ground.

      Front power window motor LH

      Ground

      Continuity

      Connector

      Terminal

      D37

      4

      Yes

    Is the inspection result normal?

    YES

    GO TO 7.

    NO

    GO TO 6.

  6. CHECK ENCODER GROUND CIRCUIT 
    1. Disconnect main power window and door lock/unlock switch connector.
    2. Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.

      Main power window and door lock/unlock switch

      Front power window motor LH

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      D35

      12

      D37

      4

      Yes

    3. Check continuity between main power window and door lock/unlock switch harness connector and ground.

      Main power window and door lock/unlock switch

      Ground

      Continuity

      Connector

      Terminal

      D35

      12

      No

    Is the inspection result normal?

    YES

    Replace front power window motor LH. Refer to FRONT REGULATOR : Removal & Installation .

    NO

    Repair or replace harness.

  7. CHECK INTERMITTENT INCIDENT 

    Refer to Inspection .

    Inspection End.