Component Inspection
- CHECK THROTTLE CONTROL MOTOR
- Turn ignition switch OFF.
- Disconnect electric throttle control actuator harness connector.
- Check resistance between electric throttle control actuator terminals as per the following.
Terminals
Resistance
1 and 2
Approx. 1 - 15 Ohm [at 25 deg.C (77 deg.F)]
Is the inspection result normal?
YES
INSPECTION END
NO
Replace electric throttle control actuator. Refer to Removal and Installation .