Inspection Procedure
- CHECK BATTERY TERMINALS CONNECTION
Check if battery terminals are clean and tight.
Is the inspection result normal?
YES
GO TO 2.
NO
Repair battery terminals connection.
- CHECK FUSE
Check that the following fuses and fusible link are not blown are not blown:
Unit
Power source (Power supply terminals)
Fuse or Fusible Link No. or Letter
Capacity
Generator
Battery (terminal 3)
26
10 A
Battery (terminal 1)
A
140 A (VQ40DE)
250 A (VK56VD)
Combination meter
Ignition switch ON (terminal 2)
12
10 A
Is the fuse or fusible link blown?
YES
Replace the blown fuse or fusible link after repairing the affected circuit.
NO
GO TO 3.
- CHECK GENERATOR GROUND TERMINAL CONNECTION
Verify connector is clean and tight.
Is the inspection result normal?
YES
GO TO 4.
NO
Repair connection.
- CHECK DRIVE BELT TENSION
Check drive belt tension. Refer to Checking Drive Belts (VQ40DE) or Checking (VK56VD).
Is the inspection result normal?
YES
Inspection End.
NO
Repair as needed.