LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Opel >> 1976 >> Opel Standard Trans >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Exhaust Emissions System - Catalytic Converters >> Testing >> Vacuum Switching Valve
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Vacuum Switching Valve

With valve removed from vehicle, apply 12 volts to connector terminals and listen for clicking of solenoid as it moves inside valve. If no clicking is heard, replace valve.