Symptom Chart

SYMPTOM CHART

Symptom Repair order Reference
The door lock control system does not operate. 1. Remove and visually check the fuse No. 3 (in the fuse & relay box) and No. 7 (in the fuse & relay box). If the fuse is blown out, replace the fuse with a new part. When there is no defective with the fuse, check the power supply and ground circuit. Ref. to CHECK POWER SUPPLY & GROUND CIRCUIT , INSPECTION, Door Lock Control System.
2. Check the power supply and ground circuit for body integrated unit. Ref. to CHECK POWER SUPPLY & GROUND CIRCUIT , INSPECTION, Door Lock Control System.
3. Check the door lock switch and the circuit. Ref. to CHECK DOOR LOCK SWITCH , INSPECTION, Door Lock Control System.
4. Check the door lock actuator and the circuit. Ref. to CHECK DOOR LOCK ACTUATOR & CIRCUIT , INSPECTION, Door Lock Control System.
The door lock switch does not operate. Check the door lock switch. Ref. to CHECK DOOR LOCK SWITCH , INSPECTION, Door Lock Control System.
A specific door lock actuator does not operate. Check the door lock actuator and circuit. Ref. to CHECK DOOR LOCK ACTUATOR & CIRCUIT , INSPECTION, Door Lock Control System.