LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Subaru >> 2009 >> Tribeca Base >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Anti-Theft System - Security And Locks >> Security System >> Inspection >> Check Hazard Light Operation
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Check Hazard Light Operation

DIAGNOSIS PROCEDURE

Step Check Yes No
1 CHECK HAZARD LIGHT OPERATION. 
Make sure the hazard light blinks when hazard switch is turned to ON.
Does the hazard light blink? Go to step 2.  Check the hazard light circuit.
2 CHECK OUTPUT TO HAZARD LIGHT. 
  1. Turn the ignition switch to OFF.
  2. Disconnect the key warning switch harness connector.
  3. Prepare the Subaru Select Monitor kit.
  4. Turn the ignition switch to ON (engine OFF), and run the "Application for Subaru Select Monitor III".
  5. On the System Selection Menu, select the {Integ. unit mode}.
  6. Select {ECM customizing}.
  7. Check the {Hazard answer-back setup}, and then switch to ON setting.
  8. Select the {Current Data Display & Save}.
  9. Remove the key from ignition switch.
  10. Check the hazard output signal of body integrated unit when operating the LOCK/UNLOCK button of transmitter.
Is output signal is present when operating the transmitter LOCK/UNLOCK button? Go to step 3.  Check the body integrated unit. Ref. to BASIC DIAGNOSTIC PROCEDURE .
3 CHECK CIRCUIT OF HAZARD LIGHT. 
  1. Turn the ignition switch to OFF.
  2. Disconnect the harness connector of body integrated unit (B280).
  3. Disconnect the turn signal and hazard unit harness connector (B32).
  4. Measure the resistance between harness connector terminals.

    Connector & terminal 

    (B280) No. 12 - (B32) No. 8: 

Is the resistance less than 10 Ω? Check the body integrated unit. Ref. to BASIC DIAGNOSTIC PROCEDURE . Repair the harness.