NOTE: Test period of each test must be within short time (3 - 5 seconds).
  1. Vacuum test

    Disconnect the harness from terminal M and connect it as shown in the illustration. Make sure the pinion gear sticks out.

    Fig 1: Testing Vacuum Operation
    G06342439Courtesy of SUBARU OF AMERICA, INC.
  2. Hold test

    Make sure the pinion gear remains stick out even after disconnecting terminal M in the above condition.

    Fig 2: Testing Hold Operation
    G06342440Courtesy of SUBARU OF AMERICA, INC.
  3. Return test

    Connect the positive terminal to terminal S and the negative terminal to terminal M and starter body to pull the pinion gear at the main contact point. Make sure the pinion gear returns to its original position when the terminal S is disconnected.

    Fig 3: Testing Return Operation
    G06342441Courtesy of SUBARU OF AMERICA, INC.