All Except TR7
- Ensure that air cleaner and engine are cold. Check position of flap valve in air cleaner snorkel. The valve should be against the cold air intake (hot air position).
- Start engine and run it until normal operating temperature is reached. Check operation of flap valve. It should move towards the hot air hose (cold air position).