Checking Power Windows




Required for troubleshooting:
- Multimeter Fluke 83
- Connector Test Kit VW7594
- Valid wiring diagram

Before starting troubleshooting, battery negative terminal (-) must be securely tighted.

Prerequisite:
- S14 Fuse 14 (10A), located on relay-panel, OK !
- S43 Circuit breaker (30A), located above fuse/relay-panel, OK !
- Supply voltage (battery-voltage) OK !


CAUTION!
DO NOT damage, enlarge or bend connector terminals or cavities by forcing probes into them when performing electrical checks. Always use connector test kit VW 1594 to make the necessary electrical connections.



Preparation:
- Remove cover from the relay panel

After repairing malfunction, check all functions of power windows, and "One touch up, one touch down" function.