Display group 6 (Basic functions)
| Display group 6 (Basic functions) | ||||||
|
||||||
| Read Measuring Value Block 6 | → | Indicated on display | ||||
| xxxx RPM | xxx% | xxx.x ° C | xx.x% | |||
| 1 | 2 | 3 | 4 | Display zones | Specification | Evaluation |
| Altitude correction factor | -50.0 to 20.0% | --- | ||||
| Intake air temperature | -48 to 110 ° C | Evaluating display group 4, display zone 4 - Intake air temperature | ||||
| Engine load | 15 to 25% | Evaluating display group 10, display zone 2 - Engine load | ||||
| Engine speed (idling speed): Manual transmission Automatic transmission | 700 to 820 RPM 640 to 760 RPM | Evaluating display group 1, display zone 1 - Engine speed (idling speed) | ||||
NOTE:
- For display zone 2:
- Engine load at idle is given as the specified value.
- For display zone 3:
- The total temperature range is given as the specification. The displayed value must be above ambient temperature.