Checking the Signal Cable Resistance To Ground
- Ignition off.
- Control module disconnected.
- Expose the combined instrument panel.
- Disconnect the combined instrument panel.
Connect an ohmmeter between terminals 19 (0 Volt) and 13 on the breakout box.
The ohmmeter should read infinite resistance.
- OK
Refer to Replacing combined instrument panel
- NOT OK
Refer to Checking for an open-circuit