LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mazda >> 2021 >> 6 Signature >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Drivers Assistance Systems - ADAS >> I-ACTIVSENSE (Service Information) >> 360°View Monitor System Aiming >> Error code 03/04/05/06/07/08/09/0A/0B/0C/0D/0E/0F/10
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Error code 03/04/05/06/07/08/09/0A/0B/0C/0D/0E/0F/10

ERROR CODE STEP AND INSPECTION DESCRIPTION

Step Inspection Action
1 VERIFY TARGET MARKER SETTING ENVIRONMENT AND POSITION
  • Verify the following.
    • The vehicle and target marker setting screen are set on level ground.
    • The target marker is set to the position indicated in the aiming procedure.
    • There is no dirt, cracks, damage, or wrinkling on the target marker.
    • The area around the camera or target marker is not shaded.
    • There is no obstruction or moving object.
    • The target marker has not moved or the target marker does not move during aiming.
  • Display the screen of the 360° view monitor system in the center display by pressing the 360° view monitor switch.
    • Does the target marker reflect light?
  • Is there a malfunction?
Yes Repair the malfunctioning location and go to the next step.
No Go to the next step.
2 PERFORM 360° VIEW MONITOR SYSTEM AIMING
  • Perform the 360° view monitor system aiming.
  • Was the 360° view monitor system aiming procedure completed correctly?
Yes The 360° view monitor system aiming is completed. Perform the 360° view monitor system screen display verification procedure.
(See 360° View Monitor System Screen Display Verification Procedure .)
No If error code 03/04/05/06/07/08/09/0A/0B/0C/0D/0E/0F/10 is displayed
  • Go to the next step.

If code other than error code 03/04/05/06/07/08/09/0A/0B/0C/0D/0E/0F/10 is displayed
  • Go to the procedure for the displayed error code.
3 VERIFY DTCs
Yes Go to the applicable DTC inspection.
(See DTC TABLE [360°VIEW MONITOR CONTROL MODULE] .)
No If the 360° view monitor system aiming is not completed correctly after performing the 360° view monitor system aiming again, replace the 360° view monitor control module.
(See 360°VIEW MONITOR CONTROL MODULE REMOVAL/INSTALLATION .)