Diagnostic Trouble Code (DTC) Chart
Diagnostics in this service information assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to: Diagnostic Methods .
Diagnostic Trouble Code Chart
| Module | DTC | Description | Action |
|---|---|---|---|
| APIM | U0136:00 | Lost Communication With Differential Control Module - Rear: No Sub Type Information | GO to Pinpoint Test BF |
| BCM | U0136:00 | Lost Communication With Differential Control Module - Rear: No Sub Type Information | GO to Pinpoint Test BF |
| BCMC | U0136:00 | Lost Communication With Differential Control Module - Rear: No Sub Type Information | GO to Pinpoint Test BF |
| BECM | U0136:00 | Lost Communication With Differential Control Module - Rear: No Sub Type Information | GO to Pinpoint Test BF |
| DCDC | U0136:00 | Lost Communication With Differential Control Module - Rear: No Sub Type Information | GO to Pinpoint Test BF |
| IPC | U0136:00 | Lost Communication With Differential Control Module - Rear: No Sub Type Information | GO to Pinpoint Test BF |
| PAM | U0136:00 | Lost Communication With Differential Control Module - Rear: No Sub Type Information | GO to Pinpoint Test BF |
| PCM | U0136:00 | Lost Communication With Differential Control Module - Rear: No Sub Type Information | GO to Pinpoint Test BF |
| SOBDMB | P0560:00 | System Voltage: No Sub Type Information | GO to Pinpoint Test A |
| SOBDMB | P0562:00 | System Voltage Low: No Sub Type Information | GO to Pinpoint Test B |
| SOBDMB | P0563:00 | System Voltage High: No Sub Type Information | GO to Pinpoint Test C |
| SOBDMB | P0600:49 | Serial Communication Link: Internal Electronic Failure | GO to Pinpoint Test D |
| SOBDMB | P0600:88 | Serial Communication Link: Bus Off | GO to Pinpoint Test D |
| SOBDMB | P060A:44 | Internal Control Module Monitoring Processor Performance: Data Memory Failure | GO to Pinpoint Test F |
| SOBDMB | P060A:47 | Internal Control Module Monitoring Processor Performance: Watchdog/Safety μC Failure | GO to Pinpoint Test F |
| SOBDMB | P060A:4A | Internal Control Module Monitoring Processor Performance: Incorrect Component Installed | GO to Pinpoint Test E |
| SOBDMB | P060A:86 | Internal Control Module Monitoring Processor Performance: Signal Invalid | GO to Pinpoint Test D |
| SOBDMB | P060A:88 | Internal Control Module Monitoring Processor Performance: Bus Off | GO to Pinpoint Test D |
| SOBDMB | P060B:47 | Internal Control Module A/D Processing Performance: Watchdog/Safety μC Failure | GO to Pinpoint Test G |
| SOBDMB | P060B:62 | Internal Control Module A/D Processing Performance: Signal Compare Failure | GO to Pinpoint Test G |
| SOBDMB | P060C:41 | Internal Control Module Main Processor Performance: General Checksum Failure | GO to Pinpoint Test H |
| SOBDMB | P060C:42 | Internal Control Module Main Processor Performance: General Memory Failure | GO to Pinpoint Test H |
| SOBDMB | P060C:44 | Internal Control Module Main Processor Performance: Data Memory Failure | GO to Pinpoint Test H |
| SOBDMB | P060C:47 | Internal Control Module Main Processor Performance: Watchdog/Safety μC Failure | GO to Pinpoint Test H |
| SOBDMB | P0613:86 | TCM Processor: Signal Invalid | GO to Pinpoint Test I |
| SOBDMB | P061A:92 | Internal Control Module Torque Performance: Performance Or Incorrect Operation | GO to Pinpoint Test J |
| SOBDMB | P061A:93 | Internal Control Module Torque Performance: No Operation | GO to Pinpoint Test J |
| SOBDMB | P0634:00 | Control Module Internal Temperature "A" Too High: No Sub Type Information | GO to Pinpoint Test K |
| SOBDMB | P064F:00 | Unauthorized Software/Calibration Detected: No Sub Type Information | GO to Pinpoint Test L |
| SOBDMB | P06A6:00 | Sensor Reference Voltage "A" Circuit Range/Performance: No Sub Type Information | GO to Pinpoint Test M |
| SOBDMB | P06A7:00 | Sensor Reference Voltage "B" Circuit Range/Performance: No Sub Type Information | GO to Pinpoint Test M |
| SOBDMB | P06A9:00 | Sensor Reference Voltage "D" Circuit Range/Performance: No Sub Type Information | GO to Pinpoint Test M |
| SOBDMB | P06B1:00 | Sensor Power Supply "A" Circuit Low: No Sub Type Information | GO to Pinpoint Test M |
| SOBDMB | P06B8:00 | Internal Control Module Non-Volatile Random Access Memory (NVRAM) Error: No Sub Type Information | GO to Pinpoint Test N |
| SOBDMB | P0887:00 | TCM Power Relay Control Circuit High: No Sub Type Information | GO to Pinpoint Test O |
| SOBDMB | P0A0A:13 | High Voltage System Interlock Circuit "A": Circuit Open | GO to Pinpoint Test P |
| SOBDMB | P0A1A:06 | Generator Control Module: Algorithm Based Failures | GO to Pinpoint Test Q |
| SOBDMB | P0A1D:08 | Hybrid/EV Powertrain Control Module "A": Bus Signal/Message Failures | GO to Pinpoint Test R |
| SOBDMB | P0A23:00 | Generator Torque Sensor Circuit Range/Performance: No Sub Type Information | GO to Pinpoint Test M |
| SOBDMB | P0A2F:94 | Drive Motor "A" Over Temperature: Unexpected Operation | GO to Pinpoint Test S |
| SOBDMB | P0A37:64 | Generator Temperature Sensor Circuit Range/Performance: Signal Plausibility Failure | GO to Pinpoint Test T |
| SOBDMB | P0A38:00 | Generator Temperature Sensor Circuit Low: No Sub Type Information | GO to Pinpoint Test T |
| SOBDMB | P0A39:00 | Generator Temperature Sensor Circuit High: No Sub Type Information | GO to Pinpoint Test T |
| SOBDMB | P0A3A:00 | Generator Temperature Sensor Circuit Intermittent: No Sub Type Information | GO to Pinpoint Test T |
| SOBDMB | P0A3C:94 | Drive Motor "A" Inverter Over Temperature: Unexpected Operation | GO to Pinpoint Test U |
| SOBDMB | P0A45:00 | Drive Motor "B" Position Sensor Circuit: No Sub Type Information | GO to Pinpoint Test V |
| SOBDMB | P0A47:00 | Drive Motor "B" Position Sensor Circuit Low: No Sub Type Information | GO to Pinpoint Test V |
| SOBDMB | P0A4C:00 | Generator Position Sensor Circuit Range/Performance: No Sub Type Information | GO to Pinpoint Test W |
| SOBDMB | P0A4D:00 | Generator Position Sensor Circuit Low: No Sub Type Information | GO to Pinpoint Test X |
| SOBDMB | P0A50:92 | Generator Position Sensor Circuit Overspeed: Performance Or Incorrect Operation | GO to Pinpoint Test Y |
| SOBDMB | P0A6F:00 | Generator Phase U Current: No Sub Type Information | GO to Pinpoint Test Z |
| SOBDMB | P0A71:00 | Generator Phase U Current High: No Sub Type Information | GO to Pinpoint Test AA |
| SOBDMB | P0A72:00 | Generator Phase V Current: No Sub Type Information | GO to Pinpoint Test Z |
| SOBDMB | P0A74:00 | Generator Phase V Current High: No Sub Type Information | GO to Pinpoint Test AA |
| SOBDMB | P0A75:00 | Generator Phase W Current: No Sub Type Information | GO to Pinpoint Test Z |
| SOBDMB | P0A77:00 | Generator Phase W Current High: No Sub Type Information | GO to Pinpoint Test AA |
| SOBDMB | P0A7A:96 | Generator Inverter Performance: Component Internal Failure | GO to Pinpoint Test AB |
| SOBDMB | P0B38:00 | Motor Electronics Coolant Pump "B" Control Circuit/Open: No Sub Type Information | GO to Pinpoint Test AC |
| SOBDMB | P0B3A:00 | Motor Electronics Coolant Pump "B" Control Circuit High: No Sub Type Information | GO to Pinpoint Test AC |
| SOBDMB | P0BCD:00 | Generator Inverter Temperature Sensor "A" Circuit Range/Performance: No Sub Type Information | GO to Pinpoint Test AD |
| SOBDMB | P0BCE:00 | Generator Inverter Temperature Sensor "A" Circuit Low: No Sub Type Information | GO to Pinpoint Test AE |
| SOBDMB | P0BCF:00 | Generator Inverter Temperature Sensor "A" Circuit High: No Sub Type Information | GO to Pinpoint Test AE |
| SOBDMB | P0BD0:00 | Generator Inverter Temperature Sensor "A" Circuit Intermittent/Erratic: No Sub Type Information | GO to Pinpoint Test AE |
| SOBDMB | P0C03:00 | Drive Motor "B" Current Low: No Sub Type Information | GO to Pinpoint Test AF |
| SOBDMB | P0C2F:62 | Internal Control Module Drive Motor/Generator-Engine Speed Sensor Performance: Signal Compare Failure | GO to Pinpoint Test AG |
| SOBDMB | P0C2F:63 | Internal Control Module Drive Motor/Generator-Engine Speed Sensor Performance: Circuit/Component Protection Time-Out | GO to Pinpoint Test AG |
| SOBDMB | P0C5A:00 | Drive Motor "B" Position Sensor Circuit "A": No Sub Type Information | GO to Pinpoint Test AH |
| SOBDMB | P0C5C:00 | Drive Motor "B" Position Sensor Circuit "A" Low: No Sub Type Information | GO to Pinpoint Test AI |
| SOBDMB | P0C5D:00 | Drive Motor "B" Position Sensor Circuit "A" High: No Sub Type Information | GO to Pinpoint Test AJ |
| SOBDMB | P0C5F:00 | Drive Motor "B" Position Sensor Circuit "B": No Sub Type Information | GO to Pinpoint Test AK |
| SOBDMB | P0C61:00 | Drive Motor "B" Position Sensor Circuit "B" Low: No Sub Type Information | GO to Pinpoint Test AL |
| SOBDMB | P0C62:00 | Drive Motor "B" Position Sensor Circuit "B" High: No Sub Type Information | GO to Pinpoint Test AM |
| SOBDMB | P0C64:00 | Generator Position Sensor Circuit A: No Sub Type Information | GO to Pinpoint Test V |
| SOBDMB | P0C65:00 | Generator Position Sensor Circuit "A" Range/Performance: No Sub Type Information | GO to Pinpoint Test AN |
| SOBDMB | P0C66:00 | Generator Position Sensor Circuit "A" Low: No Sub Type Information | GO to Pinpoint Test AO |
| SOBDMB | P0C67:00 | Generator Position Sensor Circuit "A" High: No Sub Type Information | GO to Pinpoint Test AP |
| SOBDMB | P0C6A:00 | Generator Position Sensor Circuit "B" Range/Performance: No Sub Type Information | GO to Pinpoint Test AQ |
| SOBDMB | P0C6B:00 | Generator Position Sensor Circuit "B" Low: No Sub Type Information | GO to Pinpoint Test AR |
| SOBDMB | P0C6C:00 | Generator Position Sensor Circuit "B" High: No Sub Type Information | GO to Pinpoint Test AS |
| SOBDMB | P0C79:00 | Drive Motor "A" Inverter Voltage Too High: No Sub Type Information | GO to Pinpoint Test AT |
| SOBDMB | P0DA8:00 | Hybrid/EV Battery Voltage/Drive Motor "A" Inverter Voltage Correlation: No Sub Type Information | GO to Pinpoint Test AU |
| SOBDMB | P0DFA:00 | Generator Phase U-V-W Current Sensor Correlation: No Sub Type Information | GO to Pinpoint Test AV |
| SOBDMB | P0DFC:00 | Generator Position Sensor Not Learned: No Sub Type Information | GO to Pinpoint Test AW |
| SOBDMB | P0E71:00 | Generator Torque Delivered Performance: No Sub Type Information | GO to Pinpoint Test AX |
| SOBDMB | P174E:00 | Output Shaft Speed / ABS Wheel Speed Correlation: No Sub Type Information | GO to Pinpoint Test AY |
| SOBDMB | P1A07:00 | Inverter High Voltage Performance: No Sub Type Information | GO to Pinpoint Test AZ |
| SOBDMB | P1A0A:02 | Immediate Shutdown Signal A: General Signal Failure | GO to Pinpoint Test BA |
| SOBDMB | P2D05:00 | Motor Electronics Coolant Pump "B" Stuck/Stalled: No Sub Type Information | GO to Pinpoint Test AC |
| SOBDMB | P2D06:00 | Motor Electronics Coolant Pump "B" Overspeed/Air in System: No Sub Type Information | GO to Pinpoint Test AC |
| SOBDMB | P2D07:00 | Motor Electronics Coolant Pump "B" Underspeed: No Sub Type Information | GO to Pinpoint Test AC |
| SOBDMB | P2D08:00 | Motor Electronics Coolant Pump "B" Supply Voltage Circuit: No Sub Type Information | GO to Pinpoint Test AC |
| SOBDMB | P2D09:00 | Motor Electronics Coolant Pump "B" Control Module Overtemperature: No Sub Type Information | GO to Pinpoint Test AC |
| SOBDMB | U0100:00 | Lost Communication With ECM/PCM "A": No Sub Type Information | GO to Pinpoint Test BB |
| SOBDMB | U0111:00 | Lost Communication With Battery Energy Control Module "A": No Sub Type Information | GO to Pinpoint Test BC |
| SOBDMB | U0121:00 | Lost Communication With Anti-Lock Brake System (ABS) Control Module "A": No Sub Type Information | GO to Pinpoint Test BD |
| SOBDMB | U0131:00 | Lost Communication With Power Steering Control Module "A": No Sub Type Information | GO to Pinpoint Test BE |
| SOBDMB | U0140:00 | Lost Communication With Body Control Module: No Sub Type Information | GO to Pinpoint Test BG |
| SOBDMB | U0293:87 | Lost Communication with Hybrid/EV Powertrain Control Module: Missing Message | GO to Pinpoint Test BH |
| SOBDMB | U0647:00 | Lost Communication with Motor Electronics Coolant Pump "B": No Sub Type Information | GO to Pinpoint Test AC |
| SOBDMB | U1010:00 | Invalid Internal Control Module Monitoring Data Received from Hybrid Powertrain Control Module: No Sub Type Information | GO to Pinpoint Test BI |
| SOBDMB | U1022:00 | Invalid Internal Control Module Monitoring Data Received from Body Control Module: No Sub Type Information | GO to Pinpoint Test BJ |
| SOBDMB | U2100:00 | Initial Configuration Not Complete: No Sub Type Information | GO to Pinpoint Test BK |
| SOBDMC | U0136:00 | Lost Communication With Differential Control Module - Rear: No Sub Type Information | GO to Pinpoint Test BF |